{"id":55,"date":"2015-05-30T14:30:11","date_gmt":"2015-05-30T18:30:11","guid":{"rendered":"http:\/\/mysleepguard.com\/solution\/?page_id=55"},"modified":"2019-05-07T14:01:47","modified_gmt":"2019-05-07T18:01:47","slug":"troubleshooting-guide","status":"publish","type":"page","link":"https:\/\/mysleepguard.com\/solution\/customer-service\/troubleshooting-guide\/","title":{"rendered":"Troubleshooting Guide"},"content":{"rendered":"<h5>If your SleepGuard biofeedback headband is misbehaving, this web page is here to help you figure out whether the problem is something simple that can be fixed without sending the unit to us, or whether it&#8217;s something that will require sending the unit in for service.<\/h5>\n<h3>\u00a0<strong>Please follow the steps below:<\/strong><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-144\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-1.png\" alt=\"icon-blue-number-1\" width=\"25\" height=\"25\" \/> Remove the electronic module from the headband and remove the batteries as shown in the &#8220;Replacing Batteries&#8221; section on page 12 of the <a href=\"https:\/\/mysleepguard.com\/solution\/service-refurbishment\/owners-manual\/\">manual<\/a>, then re-insert the batteries as shown.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-145\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-2.png\" alt=\"icon-blue-number-2\" width=\"25\" height=\"25\" \/> Put the battery cover back on as shown on page 12 of the <a href=\"https:\/\/mysleepguard.com\/solution\/service-refurbishment\/owners-manual\/\">manual<\/a>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-146\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-3.png\" alt=\"icon-blue-number-3\" width=\"25\" height=\"25\" \/>Make sure you tucked the two metal tabs (on the opposite end of the battery cover from the screw) into their slots in the plastic housing before tightening the screw. If you didn&#8217;t do that, remove the cover and re-install with the tabs tucked in.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-147\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-4.png\" alt=\"icon-blue-number-4\" width=\"25\" height=\"25\" \/> Press the Mode button and watch the display. The unit should give a brief double-beep, and all segments of the display should turn on at once momentarily. The display should then briefly display 0, and then change to 1 as the biofeedback tone comes on. The biofeedback tone should then sound continuously for several seconds, and then begin pulsing.<\/p>\n<p>If the unit does not turn on, or the display shows &#8220;Bat&#8221;, then the batteries need to be replaced, and the steps above should be done again. If the unit does not do everything described in step 4 above with new batteries, it needs to be sent in for service.<\/p>\n<p>If everything works as it should in step 4, continue with the steps below.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-148\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-5.png\" alt=\"icon-blue-number-5\" width=\"25\" height=\"25\" \/> If the unit is on, hold the Mode button down for one full second to turn the unit off.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-149\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-6.png\" alt=\"icon-blue-number-6\" width=\"25\" height=\"25\" \/> Briefly depress the mode button to turn the unit on, and while the tone is sounding, bend the rubber snap arms around behind the unit and touch both snaps to the stainless steel back at the same time, as shown in the photo below:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"  aligncenter wp-image-549 size-full\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-6.jpg\" alt=\"troubleshooting-6\" width=\"640\" height=\"453\" srcset=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-6.jpg 640w, https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-6-300x212.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p>\u00a0The sound should stop when the two snaps are both touching the metal back at once. If the sound does not stop, then the unit needs to be sent in for service.<\/p>\n<p>If the sound does stop in step 6 above, and the problem you had with your unit was that it was beeping when you think it should not beep, the sensor pads may need to be cleaned or replaced.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-150\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-7.png\" alt=\"icon-blue-number-7\" width=\"25\" height=\"25\" \/> To clean the sensor pads, either wipe with alcohol using a cotton ball or paper towel, or with your fingertips, wash the surface of the sensor pads with soap &amp; water and then rinse.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-151\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/icon-blue-number-8.png\" alt=\"icon-blue-number-8\" width=\"25\" height=\"25\" \/> If you or a friend has a digital multimeter, you can check the resistance of the sensor pads as shown in the photo below:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"  aligncenter wp-image-550 size-full\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-8.jpg\" alt=\"troubleshooting-8\" width=\"695\" height=\"600\" srcset=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-8.jpg 695w, https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/troubleshooting-8-300x259.jpg 300w\" sizes=\"auto, (max-width: 695px) 100vw, 695px\" \/><\/p>\n<p>If you or a friend do not have a digital multimeter, you can buy one on Amazon for as little as about $16 (for example <a href=\"https:\/\/www.amazon.com\/dp\/B07DW681FQ\/\">https:\/\/www.amazon.com\/dp\/B07DW681FQ\/<\/a>). If the resistance is above 2000 Ohms, the carbon matrix in the rubber sensor pads has degraded, and the sensor pads need to be replaced. Replacement sensor pads may be ordered by <a href=\"https:\/\/mysleepguard.com\/solution\/products-pricing\/parts-accessories\/\">clicking here<\/a>.<\/p>\n<p>&nbsp;<\/p>\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f12-o1\" lang=\"\" dir=\"ltr\" data-wpcf7-id=\"12\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/solution\/wp-json\/wp\/v2\/pages\/55#wpcf7-f12-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<div style=\"display: none;\">\n<input type=\"hidden\" name=\"_wpcf7\" value=\"12\" \/>\n<input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.0.6\" \/>\n<input type=\"hidden\" name=\"_wpcf7_locale\" value=\"\" \/>\n<input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f12-o1\" \/>\n<input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/>\n<input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/div>\n<h3 style=\"text-align: center;\"><span style=\"font-size: 20pt;\">Have questions? We can help!<\/span>\n<\/h3>\n<p><span style=\"font-size: 18pt;\"> Ask us anything related to SleepGuard\u2122 <\/span><br \/>\nYour Name: <span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span>\n<\/p>\n<p>Your Email (required): <span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span>\n<\/p>\n<p>Ask your questions here... we'll answer!<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"2\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\"><\/textarea><\/span>\n<\/p>\n<p>CAPTCHA: <input type=\"hidden\" name=\"_wpcf7_captcha_challenge_captcha-102\" value=\"3529185812\" \/><img loading=\"lazy\" decoding=\"async\" class=\"wpcf7-form-control wpcf7-captchac wpcf7-captcha-captcha-102\" width=\"84\" height=\"28\" alt=\"captcha\" src=\"https:\/\/mysleepguard.com\/solution\/wp-content\/uploads\/wpcf7_captcha\/3529185812.png\" \/><br \/>\nInput characters and click submit. <span class=\"wpcf7-form-control-wrap\" data-name=\"captcha-102\"><input size=\"10\" maxlength=\"12\" class=\"wpcf7-form-control wpcf7-captchar\" autocomplete=\"off\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"captcha-102\" \/><\/span><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Submit my Question\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>If your SleepGuard biofeedback headband is misbehaving, this web page is here to help you figure out whether the problem is something simple that can be fixed without sending the unit to us, or whether it&#8217;s something that will require sending the unit in for service. \u00a0Please follow the steps below: Remove the electronic module [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":549,"parent":57,"menu_order":3,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":{"0":"post-55","1":"page","2":"type-page","3":"status-publish","4":"has-post-thumbnail","6":"entry"},"_links":{"self":[{"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/pages\/55","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/comments?post=55"}],"version-history":[{"count":2,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/pages\/55\/revisions"}],"predecessor-version":[{"id":3505,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/pages\/55\/revisions\/3505"}],"up":[{"embeddable":true,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/pages\/57"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/media\/549"}],"wp:attachment":[{"href":"https:\/\/mysleepguard.com\/solution\/wp-json\/wp\/v2\/media?parent=55"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}